Table 18 (Cont.)
Connector and Funcon
Connector Connector Type Locaon Funcon
LCN3 SFP cage Front panel 100Base-T/1000Base-T electrical or 1000Base-SX/
LX10/EX/ZX opcal interblade communicaon
connecon for blades within one ROADM system
Note: The LCN3 port cannot be used as a
communicaon connecon to another blade or
device outside the virtual NE.
LCN4 SFP cage Front panel 100Base-T/1000Base-T electrical or 1000Base-SX/
LX10/EX/ZX opcal interblade communicaon
connecon for blades within one ROADM system
Note: The LCN4 port cannot be used as a
communicaon connecon to another blade or
device outside the virtual NE.
LMP RJ-45 Front panel 100Base-T/1000Base-T LMP connecon for cra
interface to WebGUI
MAINT RJ-45 Rear panel 100/1000Base-T connecon of maintenance port (for
Internal use only)
MON LC with shuer Front panel MON-T and MON-R have 5% (13 dB) splier
OSC LC with shuer Front panel Opcal supervisory channel connecon to/from E-SC
E1 port or F-SC E1 port
PoE
Note: Supported only on
L100 Issue 13,
FC95453R11-I13, and
earlier.
RJ-45 Front panel 10Base-T/100Base-T power over Ethernet (PoE)
connecon (for future use)
Note: The PoE applicaon and cabling is suitable for
indoor use only, and is not suitable for outside
applicaons.
CONSOLE
Note: Supported only
on L100 Issue 14,
FC95453R11-I14, and
later.
RJ-45 Front panel RS-232C Serial Interface for CRAFT IF
USB Flash Drive USB 2.0 Standard A Front panel Secondary database
USER RJ-45 Front panel User channel supports maximum 10 Mb/s for both
OC3 OSC and Ethernet OSC (100M/1GE).
UTLP RJ-45 Front panel 100Base-T/1000Base-T
Note: Connecon to L160 Raman blade.
Note: The RST push-switch is used to acvate a CPU blade soware WARM reset.
Unit Description
L100 Blade
67
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only