18
Setting the Interfaces
Setting PDH Receive Interface
Setting PDH Receive Interface
Description PDH Receive interface settings should match the network equipment
settings of Rate, Termination and Line Code and determine the Payload
to be tested.
TIP: If you wish to set the HP 37717C transmitter and receiver to the same
interface settings choose .
HOW TO: 1 Choose the required SIGNAL source.
2 If Binary Interfaces, Option UH3, is fitted, choose the INTERFACE
required. See "Setting PDH Receive Binary Interface " page 20.
3 If you have chosen 2 Mb/s as the PDH signal rate, choose the required
impedance (TERMINATION). At all other rates the impedance is
fixed.
4 If you have chosen 2 Mb/s, 8 Mb/s or DS1 (Option 110) as the PDH
signal rate, choose the required LINE CODE. At 140 Mb/s, 34 Mb/s
and DS3 coding is fixed.
5 If you are measuring at the network equipment monitor point set the
LEVEL field to MONITOR.
OTHER
SETTINGS CONTROL COUPLED
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com