HP P2000 G3 MSA System CLI Reference Guide 281
show sensor-status
Description Shows the status of each environmental sensor in each enclosure.
Information shown only for a controller enclosure: on-board temperature, disk controller temperature,
memory controller temperature, super-capacitor voltage and charge, overall unit (enclosure) status.
Information shown for all enclosures except D2700 and MSA70: temperature, voltage, and current
for each IOM (controller module or expansion module); temperature, voltage, and current for each
PSU (power supply).
Information shown for D2700 and MSA70 enclosures: temperature for each IOM (expansion
module) and PSU (power supply).
Normal and error ranges for temperature and voltage are specified in the User Guide.
Syntax
show sensor-status
Output Encl
Enclosure number.
Sensor Name
Sensor name and location.
Value
• For a sensor, its value.
• For overall unit status, one of the status values below.
Status
• OK: The sensor is present and detects no error condition.
• Warning: The sensor detected a non-critical error condition. Temperature, voltage, or current is
between the warning and critical thresholds.
• Error: The sensor detected a critical error condition. Temperature, voltage, or current exceeds
the critical threshold.
• Unavailable: The sensor is present with no known errors, but has not been turned on or set
into operation because it is initializing. This typically occurs during controller startup.
• Unrecoverable: The enclosure management processor (EMP) cannot communicate with the
sensor.
• Unknown: The sensor is present but status is not available.
• Not Installed: The sensor is not present.
• Unsupported: Status detection is not implemented.
Example Show sensor status for a system that includes a controller enclosure and a D2700 drive enclosure:
# show sensor-status
Encl Sensor Name Value Status
---------------------------------------------------------
1 On-Board Temperature 1-Ctlr A 49 C OK
1 On-Board Temperature 1-Ctlr B 43 C OK
1 On-Board Temperature 2-Ctlr A 62 C OK
1 On-Board Temperature 2-Ctlr B 56 C OK
1 On-Board Temperature 3-Ctlr A 48 C OK
1 On-Board Temperature 3-Ctlr B 46 C OK
1 Disk Controller Temp-Ctlr A 27 C OK
1 Disk Controller Temp-Ctlr B 26 C OK
1 Memory Controller Temp-Ctlr A 67 C OK
1 Memory Controller Temp-Ctlr B 58 C OK