compact-flash
Properties
Example
# show controllers
...
<OBJECT basetype="compact-flash" name="controller-a-compact-flash" oid="8"
format="pairs">
<PROPERTY name="durable-id" type="string">Ctlr A CF</PROPERTY>
<PROPERTY name="controller-id" type="string">A</PROPERTY>
<PROPERTY name="controller-id-numeric" type="string">1</PROPERTY>
<PROPERTY name="name" type="string">Controller A CompactFlash</PROPERTY>
<PROPERTY name="status" type="string">Installed</PROPERTY>
<PROPERTY name="status-numeric" type="string">1</PROPERTY>
<PROPERTY name="cache-flush" type="string">Disabled</PROPERTY>
<PROPERTY name="cache-flush-numeric" type="string">0</PROPERTY>
<PROPERTY name="health" type="string">OK</PROPERTY>
Table 17 compact-flash properties
Name Type Description
durable-id string • Ctlr A CF: CompactFlash card in controller A.
• Ctlr B CF: CompactFlash card in controller B.
controller-id string • A: Controller A.
• B: Controller B.
controller-id-
numeric
string Numeric equivalents for controller-id values.
• 0: B
• 1: A
name string • Controller A CompactFlash
• Controller B CompactFlash
status string • Not Installed
• Installed
status-numeric string Numeric equivalents for status values.
• 0: Not Installed
• 1: Installed
cache-flush string • Enabled: If the controller loses power, it will automatically write cache data
to the CompactFlash card. Cache flush is normally enabled, but is
temporarily disabled during controller shut down.
• Disabled: Cache flush is disabled.
cache-flush-
numeric
string Numeric equivalents for cache-flush values.
• 0: Disabled
• 1: Enabled
health string • OK
• Fault
• N/A
health-numeric string Numeric equivalents for health values.
• 0: OK
• 2: Fault
• 4: N/A
health-reason string If Health is not OK, the reason for the health state.
health-
recommendation
string If Health is not OK, the recommended action to take to resolve the health issue.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
BrandHP
ModelP2000 G3
CategoryStorage
LanguageEnglish

Related product manuals