440 XML API basetype properties
redundancy
Properties
Table 54 redundancy properties
Name Type Description
redundancy-mode string The system’s operating mode, also called the cache redundancy mode.
• Active-Active ULP: Both controllers are active using ULP (Unified LUN
Presentation). Data for volumes configured to use write-back cache is
automatically mirrored between the two controllers to provide fault
tolerance.
• Single Controller: The enclosure contains a single controller.
• Fail Over: Operation has failed over to one controller because its partner
is not operational. The system has lost redundancy.
• Down: Both controllers are not operational.
redundancy-
mode-numeric
string Numeric equivalents for redundancy-mode values.
• 2: Active-Active ULP
• 3: Single Controller
• 4: Fail Over
• 5: Down
redundancy-
status
string • Redundant: Both controllers are operational.
• Operational but not redundant: In active-active mode, one
controller is operational and the other is offline. In single-controller mode,
the controller is operational.
• Down: This controller is not operational.
• Unknown: Status information is not available.
redundancy-
status-numeric
string Numeric equivalents for redundancy-status values.
• 1: Redundant
• 3: Operational but not redundant
• 4: Down
• 5: Unknown
controller-a-
status
string • Operational: The controller is operational.
• Down: The controller is installed but not operational.
• Not Installed: The controller is not installed.
controller-a-
status-numeric
string Numeric equivalents for controller-a-status values.
• 0: Operational
• 1: Down
• 2: Not Installed
controller-a-
serial-number
string • Controller module serial number
• Not Available: The controller is down or not installed.
controller-b-
status
string • Operational: The controller is operational.
•
Down: The controller is installed but not operational.
• Not Installed: The controller is not installed.
controller-b-
status-numeric
string Numeric equivalents for controller-b-status values.
• 0: Operational
• 1: Down
• 2: Not Installed
controller-b-
serial-number
string • Controller module serial number
• Not Available: The controller is down or not installed.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
BrandHP
ModelP2000 G3
CategoryStorage
LanguageEnglish

Related product manuals