382 XML API basetype properties
disk-statistics
Properties
Table 23 disk-statistics properties
Name Type Description
durable-id string Disk ID in the form disk_enclosure-number.disk-number.
serial-number string Disk serial number.
bytes-per-
second
string Data transfer rate calculated over the interval since these statistics were last
requested or reset. This value will be zero if it has not been requested or reset
since a controller restart.
bytes-per-
second-numeric
string Unformatted bytes-per-second value.
iops uint32 Input/output operations per second, calculated over the interval since these
statistics were last requested or reset. This value will be zero if it has not been
requested or reset since a controller restart.
number-of-reads uint64 Number of read operations since these statistics were last reset or since the
controller was restarted.
number-of-
writes
uint64 Number of write operations since these statistics were last reset or since the
controller was restarted.
data-read string Amount of data read since these statistics were last reset or since the controller
was restarted.
data-read-
numeric
string Unformatted data-read value.
data-written string Amount of data written since these statistics were last reset or since the controller
was restarted.
data-written-
numeric
string Unformatted data-written value.
queue-depth uint32 Number of pending I/O operations currently being serviced.
reset-time string Date and time, in the format year-month-day hour:minutes:seconds,
when these statistics were last reset, either by a user or by a controller restart.
reset-time-
numeric
string Unformatted reset-time value.
start-sample-
time
string Date and time, in the format year-month-day hour:minutes:seconds,
when sampling started for the iops and bytes-per-second values.
start-sample-
time-numeric
string Unformatted start-sample-time value.
stop-sample-
time
string Date and time, in the format year-month-day hour:minutes:seconds,
when sampling stopped for the iops and bytes-per-second
values.
stop-sample-
time-numeric
string Unformatted stop-sample-time value.
smart-count-1 uint32 For port 1, the number of SMART events recorded.
io-timeout-
count-1
uint32 For port 1, the number of timeouts accessing the disk.
no-response-
count-1
uint32 For port 1, the number of times the disk did not respond.
spinup-retry-
count-1
uint32 For port 1, the number of attempts by the storage system to spin up the disk.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
BrandHP
ModelP2000 G3
CategoryStorage
LanguageEnglish

Related product manuals