l In the case of non-authentication or password authentication, the level of the command that
the user can run is determined by the level of the user interface.
l In the case of AAA authentication, the command that the user can use is determined by the
level of the local user specified in the AAA configuration.
4.2 Configuring the Console User Interface
If you log in to the device through a console port to perform local maintenance, you can configure
attributes for the console user interface as needed.
4.2.1 Establishing the Configuration Task
Before configuring the console user interface, familiarize yourself with the applicable
environment, complete the pre-configuration tasks, and obtain any data required for the
configuration. This will help you complete the configuration task quickly and correctly.
Applicable Environment
If you need to log in to the router through a console port to perform local maintenance, you can
configure the corresponding console user interface, including the physical attributes, terminal
attributes, user priority, and user authentication mode. These parameters have default values that
require no additional configuration, but you may modify these parameters as needed.
Pre-configuration Tasks
Before configuring a console user interface, complete the following tasks:
l Logging in to the router with a terminal
Data Preparation
To configure a console user interface, you need the following data.
No.
Data
1 Baud rate, flow-control mode, parity, stop bit, and data bit
2 Idle timeout period, terminal screen length, and the size of history command buffer
3 User priority
4 User authentication method, username, and password
NOTE
All the default values (excluding the password and username) are stored on the router and do not need
additional configuration.
4.2.2 Setting Physical Attributes of the Console User Interface
You can configure the rate, flow control mode, parity mode, stop bit, and data bit for the console
port.
Huawei AR1200 Series Enterprise Routers
Configuration Guide - Basic Configuration 4 Configuring User Interfaces
Issue 04 (2012-05-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
45

Table of Contents

Other manuals for Huawei AR1200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei AR1200 Series and is the answer not in the manual?

Huawei AR1200 Series Specifications

General IconGeneral
BrandHuawei
ModelAR1200 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals