5486IOA.fm Draft Document for Review October 18, 2004
378 IBM Eserver i5 and iSeries System Handbook
The #2782 is withdrawn from marketing in October 2004. The #2787 PCI-X
Fibre Channel Disk Controller is the recommended replacement.
#2782 PCI-X RAID Disk Unit Controller
The #2782 PCI-X RAID Disk Unit Controller is an Ultra SCSI disk unit controller
with a 40 MB cache that provides RAID-5 protection for internal disk units. It also
supports internal tape devices, CD-ROM, and DVD units. The #2782 has two
Ultra SCSI buses.
The #2782 is designed to work as a high performance controller for disks
protected by system mirroring or disks with no protection. In the RAID-5
configuration, disk unit protection is provided at less cost than mirroring, and with
greater performance than system checksums.
The #2782 controller supports a maximum of 12 disk units. DASD compression
is not supported.
The #2782 controls up to two removable media devices (internal tape, CD-ROM
and DVD).
A minimum of three disk units of the same capacity are needed for a valid
RAID-5 configuration. A maximum of four arrays are allowed per controller, with a
maximum of 12 disk units allowed per array.
Parity is spread across either two, four, eight, or 16 disk units in an array, as
represented in the following table.
Important: A #2766 PCI Fibre Channel Disk Controller, supported on the
iSeries with OS/400 V5R1, can be used to attach the IBM TotalStorage
Enterprise Storage Server (ESS). The #2766 is not supported as a load
source IOP in secondary (system is unable to IPL via a #2766), but remote
load source mirroring is supported through the #2766.
Note: Due to a system unit and external tower disk cage designs, only the
Models 270 and 810, and the #0595/#5095 PCI-X Expansion Tower have a
suitable system configuration to allow 12 disk units to attach to a single #2782.
All other system unit and tower disk configurations restrict the number of
attaching disk units to 10 or less.

Table of Contents

Other manuals for IBM eserver i5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM eserver i5 and is the answer not in the manual?

IBM eserver i5 Specifications

General IconGeneral
BrandIBM
Modeleserver i5
CategoryServer
LanguageEnglish

Related product manuals