Ethernet Subnetmask: [255.255.255.0]
Ethernet IP Address: [192.168.74.102]
Gateway IP Address: [192.168.74.1]
4. Enter off to disable DHCP when prompted.
DHCP [OFF]: off
Setting the date and time
About this task
The date and time settings are used for logging events, error detection, and troubleshooting. However,
device operation does not depend on the date and time; a device with incorrect date or time values still
functions properly.
You can synchronize the local time of the principal or primary fabric conguration server (FCS) device to
that of an external Network Time Protocol (NTP) server.
Perform the following steps to set the date and time.
Procedure
1. Log in to the device as admin.
2. Enter the date["newdate"] command at the command line.
The newdate variable species the new date and time enclosed in double quotation marks. The
operand is optional; if omitted, the current date and time is displayed. Date and time are specied as a
string in the mmddhhmmyy format:
mm: Species the month. Valid values are 01 to 12.
dd: Species the date. Valid values are 01 to 31.
hh: Species the hour. Valid values are 00 to 23.
mm: Species the minutes. Valid values are 00 to 59.
yy: Species the year, valid values are 00 to 37 and 70 to 99. Year values from 70 to 99 are
interpreted as 1970 to 1999; year values from 00 to 37 are interpreted as 2000 to 2037.
device:admin> date
Thu Dec 22 14:05:10 UTC 2016
device:admin> date "1222150617"
Thu Dec 22 15:06:00 UTC 2017
Setting the time zone
About this task
The default time zone is Coordinated Universal Time (UTC). The time zone must be set only once because
the value is stored in nonvolatile memory. Use the following procedure to set the time zone.
Procedure
1. Log in as admin.
2. Use thetsTimeZone --interactive command and follow the prompts, or enter thetsTimeZone
[houroffset [,minuteoffset]] command as follows:
For Pacic Standard Time, entertsTimeZone -8,0.
For Central Standard Time, entertsTimeZone -6,0.
For Eastern Standard Time, entertsTimeZone -5,0.
40
IBM Storage Networking SAN64B-6: SAN64B-6 Installation, Service, and User Guide

Table of Contents

Other manuals for IBM SAN64B-6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN64B-6 and is the answer not in the manual?

IBM SAN64B-6 Specifications

General IconGeneral
BrandIBM
ModelSAN64B-6
CategorySwitch
LanguageEnglish

Related product manuals