Fabric param (yes, y, no, n): [no] y
d) Enter a unique domain ID (such as the domain ID used by the previous switch, if still available).
Domain: (1..239) [1] 3
e) Complete the remaining prompts or press Ctrl+D to accept the remaining settings without
completing all the prompts.
f) Re-enable the switch by entering the switchEnable command.
Verifying correct operation
About this task
Perform the following steps to verify correct operation of the device.
Procedure
1. Check the LEDs to verify that all components are functional.
2. Verify the correct operation of the device by entering the following commands from the workstation.
Command Description
psShow Displays power supply status and information
fanShow Displays fans status and information
switchShow Displays switch status and information
tempShow Displays temperature status and information
historyShow Displays the device history
errDump Displays any errors
The switchShow command provides the following information about the device and ports status.
switchG620-2:admin> switchshow
switchName: E_G620_2_C5c_146192
switchType: 183.0
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 192
switchId: fffcc0
switchWwn: 10:00:d8:1f:cc:04:56:e0
zoning: ON (fos6k)
switchBeacon: OFF
FC Router: OFF
Fabric Name: 0123456_FID1
HIF Mode: OFF
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Ficon Switch: No, Address
Mode 0]
Index Port Address Media Speed State Proto
==================================================
0 0 c00000 id N16 No_Light FC
1 1 c00100 id N16 No_Light FC
2 2 c00200 id N16 No_Light FC
3 3 c00300 id N16 No_Light FC
4 4 c00400 id N16 No_Light FC
5 5 c00500 id N16 No_Light FC
6 6 c00600 id N16 No_Light FC
7 7 c00700 id N16 No_Light FC
8 8 c00800 id N16 No_Light FC
9 9 c00900 id N16 No_Light FC
10 10 c00a00 id N16 No_Light FC
11 11 c00b00 id N16 No_SigDet FC Disabled (Port Throttled)
12 12 c00c00 id N16 No_Light FC
13 13 c00d00 id N16 No_Light FC
Chapter 4. Initial setup and
verication 43