5-2
Spectrum scope screen
This DSP-based spectrum scope allows you to dis-
play the frequency and relative signal strength of
received signals on the strengths of signals. The
IC-7700 has two modes for the spectrum display
oneiscentermode,andtheotherisfixedmode.
In addition, the IC-7700 has a mini scope screen to
save screen space.
D Center mode
Displays signals around the set frequency within the
selected span. The set frequency is always displayed
at the center of the screen.
q Push
EXIT/SET
several times to close any multi-
function screens, if necessary.
w Push [SCOPE]
F-1
to select the scope screen.
•Push[WIDE]
F-7
to toggle the screen size be-
tween normal and wide.
e Push [CENT/FIX]
F-5
to select the center mode.
•“
CENTER
is displayed when center mode is selected.
r Push [SPAN]
F-1
several times to select the
scope span.
•±2.5,±5.0,±10,±25,±50,±100and±250kHzarese-
lectable.
•Holddown[SPAN]
F-1
for 1 second to return to ±2.5
kHz span.
•Sweepspeedisselectableforeachspanindepend-
ently in scope set mode. (pp. 5-5, 5-6)
t Push [ATT]
F-2
several times to activate an at-
tenuator or turn the attenuator OFF.
•10,20and30dBofattenuationisavailable.
•Holddown[ATT]
F-2
for 1 second to turn OFF the at-
tenuator.
y Push [MARKER]
F-3
to turn the marker for trans-
mit frequency ON or OFF.
•“
T
displays the marker at the transmit frequency.
•“<<”or“>>”appearswhenthemarkerisoutofrange.
•Thespectrumscopeshowsthetransmitsignalwhile
transmitting. This can be deactivated in scope set
mode. (p. 5-5)
•Thespectrumscopeshowsthepeaklevelholdfunc-
tion. Peak levels are displayed in the background of the
current spectrum in a different color until the receive
frequency changes. This can be deactivated and the
waveform color can be set in scope set mode. (p. 5-5)
u Push [HOLD]
F-4
to freeze the current spectrum
display.
•“
HOLD
appears while the function is in use.
•Thepeakholdfunctioncanbedeactivatedinscopeset
mode.
i Push
EXIT/SET
toexitthescopescreen.
NOTE: If a strong signal is received, a ghost signal
may also appear. Push [ATT]
F-2
several times to
activate the spectrum scope attenuator in this case.
Spurious signals may be displayed. They are gen-
erated in the internal scope circuit and do not indi-
cate a transceiver malfunction.
F-2
AT T
F-4
HOLD
F-1
SPAN
F-7
WIDE
F-3
MARKER
F-5
CENT/FIX
EXIT/SET
5
FUNCTIONS FOR RECEIVE
• Scope spurious signal example
Spurious signals may be received on the spectrum
scope screen regardless of the transceiver’s state
(TX or RX). They are generated in the scope circuit.
This does not indicate a transceiver malfunction.
Scope spurious example
• Spectrum scope
Waterfall

Table of Contents

Other manuals for Icom IC-7700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-7700 and is the answer not in the manual?

Icom IC-7700 Specifications

General IconGeneral
BrandIcom
ModelIC-7700
CategoryTransceiver
LanguageEnglish

Related product manuals