7 Troubleshooting
-
264
-
7.1 Elevator Fault Display
When the controller detects faults, it alerts and records related information:
The keypad displays the current fault code and subcode, such as E22-101.
󶙽Fault code and subcode display on the keypad
When an operation panel is connected, it displays the current fault code, such as
Err22.
MF.KRUN
STOP
RES
QUICK
PRG ENTER
RUN
LOCAL/ REMOT FWD/ REV TUNE/TC
RPM
%
A VHz
󶙽Fault code display on the operation panel
When F-2 is set to 2 with the keypad, it displays the information about the last 10
faults, including fault code, subcode, and time.
The integrated elevator controller records detailed information about the last 10 faults
and simple information about 50 groups of faults. For details, refer to the parameter
description of groups E0 to E9 and FC-11 to FC-210.