9 Description of Functions and Schemes
-
314
-
9.9 VIP Running Function
1 Function description
provides services for VIP persons.
■
After entering the VIP state, the elevator clears current hall calls, and does not
respond to hall calls; door open or close needs to be controlled manually.
■
The elevator does not close the door automatically. You need to hold down the
door close button to close the door. During door close, if you release the door close
button, the elevator opens the door again automatically.
■
The VIP running times is set in F6-46 Bit8.
■
F6-46 Bit8 = 0: The number of car calls is not limited. The elevator automatically
exits the VIP state in one of the following conditions:
It does not enter the car call running within 30s after each time stop. It has executed
all car calls.
There is no car call 30s after the elevator enters the VIP state.
2 Wiring
When FD-07/08 is set to 4, the elevator
enters the VIP state.
S1
CN1
JP1
JP2
JP3
JP4
UP
DOWN
MCTC- HCB-H
1 2 3 4
VIP input
HCB JP1/JP2 input
Wiring diagram of VIP enabled by HCB