EasyManuals Logo
Home>Juniper>Network Router>E Series

Juniper E Series User Manual

Juniper E Series
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
E-series Hardware Guide
106 ! Understanding Status LEDs to Troubleshoot
Redundancy Status
You can determine the redundancy state of line modules by examining the online
and redundant status LEDs (ERX-7xx/14xx models only). See Table 15.
! FAN OK does not light
! FAN FAIL LED lights
! Fan is not working properly or has
slowed down.
! Fan needs replacement.
Contact Juniper Networks Customer Service; the system
must be serviced.
LINK LED is not lit
! Ethernet connection is down. 1. Check that Ethernet cables are properly connected to
both the Ethernet port and the appropriate network
device.
2. Contact Juniper Networks Customer Service.
RED ALM
! System does not recognize a port
connection.
! Cabling is not connected properly.
! Cable is faulty.
! Clocking problem exists.
1. Check that all cables are firmly plugged into the ports
and the attached network device.
2. Verify that cables are clean.
3. Test for faulty cables.
4. Verify clock source and configuration.
5. Reset system.
NOTE: Problem is corrected when normal LED activity is
observed.
YEL ALM
NOTE: This LED is not
functional on the HSSI
line module.
! Far end receive failure (FERF)
exists.
1. Correct FERF problem.
2. Reset system.
NOTE: Problem is corrected when normal LED activity is
observed.
! System will not boot.
! Module(s) held offline.
! FAIL LED lights.
A slot group is overloaded. 1. Issue the show version command to display board
status.
2. Review section on proper slot group configuration in
Chapter 5, Installing Modules.
3. Reconfigure system with correct slot group
configuration.
4. Reset system.
None
! System temperature is too high.
! Vents are blocked.
! Fans are not operating.
1. Check your console for a message indicating the
problem. If you have the system log set to a severity of
WARNING or higher, a Warning message indicating the
failure is displayed.
2. Issue the show environment command to display the
temperatures. If the temperature is too high, power
down the system.
3. Regulate temperature.
4. Reset system.
Table 14: Troubleshooting abnormal LED activity on modules (continued)
Diagnostic Signs Possible Problems Actions
NOTE: The REDUNDANT LED on the cOCx/STMx, FE-8, GE/FE, HSSI, and
OCx/STMx modules is nonfunctional.

Table of Contents

Other manuals for Juniper E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper E Series and is the answer not in the manual?

Juniper E Series Specifications

General IconGeneral
BrandJuniper
ModelE Series
CategoryNetwork Router
LanguageEnglish

Related product manuals