E-series Hardware Guide
62 ! Cabling the E-series Router for Power
Table 9: Power input module cables/wires needed
Cable/Wire From To
ERX-14xx models
One 10-AWG ground wire Power input module ground
terminal
Termination ground
Two 6-AWG wire leads Power input module Power A
–48 VDC and RTN leads
Appropriate leads on power
source No. 1
Two 6-AWG wire leads Power input module Power B
–48 VDC and RTN leads
Appropriate leads on power
source No. 2
ERX-7xx models
One 10-AWG ground wire Power input module ground
terminal
Termination ground
Two 10-AWG wire leads Power input module Power A
–48 VDC and RTN leads
Appropriate leads on power
source No. 1
Two 10-AWG wire leads Power input module Power B
–48 VDC and RTN leads
Appropriate leads on power
source No. 2
ERX-310 router
One 10-AWG ground wire Power input module ground
terminal
Termination ground
Two 14-AWG wire leads
NOTE: DC model only
Power input module Power A
–48 VDC and RTN leads
Appropriate leads on power
source No. 1
Two 14-AWG wire leads
NOTE: DC model only
Power input module Power B
–48 VDC and RTN leads
Appropriate leads on power
source No. 2
One AC power cord
NOTE: AC model only
Power input module AC power IEC
receptacle
Appropriate AC power
supply

Table of Contents

Other manuals for Juniper E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper E Series and is the answer not in the manual?

Juniper E Series Specifications

General IconGeneral
BrandJuniper
ModelE Series
CategoryNetwork Router
LanguageEnglish

Related product manuals