E2-60 Electrical Propulsion Components 2/02 E02016
Note: The changes made above are only temporary.
When the proper adjustment value has been
determined, the truck configuration file should be
permanently changed by entering this value on the
TRUCK SPECIFICS SCREEN. This screen is
accessed by returning to the GE OHV STATEX III
MENU, selecting “TRUCK SETUP (CFG)”, and then
line 5); “Change/view Truck Specifics”.
“TEMPORARY EVENT DATA COLLECTION INTER-
VAL”
This feature will allow changing the event data collec-
tion interval to a more frequent or less frequent period.
This feature may be necessary during troubleshooting
procedures to capture system operation over a differ-
ent time period other than normally used.
1. Select “EVENT DATA COLLECTION INTERVAL”
from the TEMPORARY TRUCK SETTINGS
MENU and press [ENTER].
2. Type the desired interval on the TEMPORARY
EVENT DATA COLLECTION INTERVAL
SCREEN.
Note: This new setting will remain in effect until it is
changed again on this screen or when power is cycled
on and off.
3. Move the cursor to select ACTIVATE TEMPO-
RARY EVENT DATA COLLECTION INTERVAL
and press [ENTER].
MISCELLANEOUS FEATURES
SAVING DATA
Various screens showing event data, digital input and
output test data, real time data, etc. can be saved to
the PTU.
Many screens will have a selection labelled “GET1”.
When selected, the data gathered and displayed on the
screen will be suspended and can then be saved per-
manently to a file. If this selection is available, it should
be chosen before pressing [F2] to save to a file.
To use this feature:
1. When it is desired to save the screen display,
select “GET1” using the arrow keys and press
[ENTER].
2. Press [F2] to save the screen to a file.
a. Follow the screen instructions for assigning a
file name and location for storing the file.
b. After the file has been saved, the PTU screen
data will remain suspended until the next step
is completed.
3. Selecting “GET1” again will update the screen
with new data and hold it there. Step 2. may be
repeated to save the updated data if desired.
4. To resume and allow the data to be continuously
updated, move the cursor to REPEAT” and
press [ENTER].
If the “GET1” selection is not available, the [F2] key is
used to save the screen display when applicable. The
availability of the [F2] key for saving the data will be
shown at the bottom of the screen.

Table of Contents

Other manuals for Komatsu 830E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu 830E and is the answer not in the manual?

Komatsu 830E Specifications

General IconGeneral
BrandKomatsu
Model830E
CategoryTrucks
LanguageEnglish

Related product manuals