E03012 2/02 Statex III Electrical Checkout Procedure E3-1
STATEX III ELECTRICAL SYSTEM CHECKOUT PROCEDURE
G E N E R A L I N F O R M A T I O N
This checkout procedure describes test and adjustment procedures for the G.E. STATEX III Electric
Wheel Drive Systems used on Model 445E, 510E, 630E, 685E, 730E, and 830E electric drive trucks
with the following alternator and wheelmotor combinations.
This system is capable of developing high voltage. Use caution when
working with the system.
The test and adjustment procedures list standard and
optional equipment which may be installed. It is the responsi-
bility of the personnel using this Electrical Checkout Proce-
dure to determine what equipment is installed on the truck
being serviced and to select the applicable test and adjust-
ment procedure.
If any of the cards in the FL275 panel must be removed, a
wrist ground strap MUST be worn to ground personnel to the
truck chassis to prevent static discharge damage to the cir-
cuit boards. After the board has been removed from the
panel, it must immediately be placed in a static-free protec-
tive bag.
Sample PTU screens illustrated in the following pages show menus and data screens as they appear
in the April, 2001 STATEX III Enhanced Version 1.00 software release. Instructions are also applica-
ble to the April 2000, version 14.00 software release. Later versions of the software may differ.
The following type fonts and styles are used to differentiate between menu titles, screen titles, menu
selections and keyboard keys to be pressed:
TRUCK MODEL ALTERNATOR WHEELMOTOR
445E, 510E GTA-25 GE772, GE776, GE791
630E, 685E, 730E GTA-22 GE776, GE788
630E, 685E, 830E GTA-26 GE788, GE787
CONVENTION APPLIES TO SAMPLE
Bold Type Menu & Screen Titles GE OHV STATEX III MENU
“Quotation Marks” Menu Selection Choices “PTU TALK TO TRUCK”
[Brackets] Key to be pressed [ENTER], [ESC], [DEL] etc.