Configuration
7-93
48XX/49XXSHB0399
7.6.3 n controller adaptation
Purpose
The adaptation of the speed controller is to improve the control behaviour. It is
recommended for
( low speed set-values (start)
( set-value jumps from n
x
-> 0 (stop) without return and drives with high
inertias.
Adaptation via characteristic
4900Str080
V
V
V (C 0 7 0 )
V
p
n
0
n
1
p1
p2
p3
n
set
l
Input data:
V
p1
= C070 (default setting = 8)
V
p2
= C320 (default setting = 8)
V
p3
= C321 (default setting = 8)
n
0
= C323 (default setting = 50rpm)
n
1
= C322 (default setting = 3000rpm)
n
set
= C050 as absolute value
l
Display value
V
pactual
= C319
l
Conditions
1.n
set
<n
0
valid for V
p3
2.n
0
<n
set
< n1 valid:
V
V
V (C 0 7 0 )
V
p
n
0
n
1
p1
p2
p3
n
set
VV
VV
nn
nn
pp
pp
set
=+
-
-
-
2
12
10
0
()
V
V
V (C 0 7 0 )
V
p
n
0
n
1
p1
p2
p3
n
set
3.n
set
>n
1
valid for V
p1
(C070)
FIG 7-53 Characteristic for internally derived n controller adaptation
The n controller adaptation is enable under C324 = -1-. The input of the n
controller adaptation must not be assigned with an analog signal (see C145 /
C146).
Adaptation via analog input terminal
V
V (C 0 7 0 )
V
p
0
p1
p2
V
max
V
input
l
Input data:
V
p1
= C070
V
p2
= C320
l
Display value
V
pactual
=C319
l
Conditions
1.if V
input
=0,V
p2
2.if V
input
<V
max
:
4900Str081
V
V (C 0 7 0 )
V
p
0
p1
p2
V
max
V
input
V
V
V
V
V
pp
pp
=+
-
2
1
2
max
V
input
.
V
V (C 0 7 0 )
V
p
0
p1
p2
V
max
V
input
3.if V
input
V
max
,V
p1
(C070)
FIG 7-54 Characteristic for external selection of the n controller adaptation
The n controller adaptation is enable under C324 = -1-. The input of the n