9300 Servo PLC
System blocks
2.3 AIF3_IO_AutomationInterface
2-13
L
ServoPLC EN 2.0
2.3.2 Outputs_AIF3
Automation interface (module number 43)
This SB is used as interface for output signals (e.g. setpoint/actual value) from attached fieldbus
modules (e. g. INTERBUS, PROFIBUS-DP).
• Theprocessimageis
– created every 10 ms.
– created in an interval task within the time set for this task.
– read at the beginning of the task and written at its end.
Tip!
Please observe the corresponding Operating Instructions for the fieldbus module that is plugged in.
Outputs_AIF3
Automation
Interface
...
Byte
1
Byte
2
Byte
3
Byte
4
Byte
5
Byte
6
Byte
7
Byte
8
...
16 Bit
LowWord
16 Bit
HighWord
16 Bit
16 binary
signals
16 Bit
16 binary
signals
AIF3_nOutW2_a
AIF3_nOutW1_a
AIF3_bFDO0_b
AIF3_bFDO15_b
AIF3_bFDO16_b
AIF3_bFDO31_b
16 Bit
16 Bit
AIF3_nOutW4_a
AIF3_dnOutD1_p
AIF3_nOutW3_a
Fig. 2-6 Outputs_AIF3
Variable name
Data type Signal type Address DIS DIS format Note
AIF3_nOutW1_a %QW43.0
AIF3_nOutW2_a
%QW43.1
AIF3_nOutW3_a
In
eger analog
%QW43.2
AIF3_nOutW4_a %QW43.3
AIF3_bFDO0_b %QX43.0.0
... ...
AIF3_bFDO15_b
%QX43.0.15
AIF3_bFDO16_b
Bool binary
%QX43.1.0
... ...
AIF3_bFDO31_b %QX43.1.15
AIF3_dnOutD1_p Double-integer position %QD43.0