10. Technologies HDMI-3D-OPT series – User's Manual 86
10
Technologies
The following sections contain descriptions and useful technical information
how the devices work in the background. The content is based on experiences
and cases we met in the practice. These sections help to understand features
and technical standards like the followings:
Î 
Î 
Î 
EDID Management
Understanding the EDID
         

about the capabilities of the display, such as supported resolutions,
refresh rates (these are called Detailed Timings), the type and
manufacturer of the display device, etc.
           
reads out the EDID to determine the resolution and refresh rate of the
image to be transmitted.
Who are
you?
I am a monitor.
Here is my EDID.
Now I know what
I can send.
EDID Communication
        
However, Digital Televisions and HDMI capable displays may have
          
(Consumer Electronics Association). This extension contains
information about additional Detailed Timings, audio capabilities,
speaker allocation and HDMI capabilities. It is important to know that
all HDMI capable devices must have CEA extension, but not all devices
with CEA extension are HDMI capable.
Common Problems Related to EDID
Problem: “My system consists of the following: a computer, a
      



Solution: If you want to see the image on both displays, you need
to select the resolution of the smaller display (in this

the higher resolution image.
Problem: “I have changed to a different EDID on an input port of
the Lightware device to have a different resolution but

Solution: Some graphics cards and video sources read out the
EDID only after power-up and later they do not sense that
EDID has been changed. You need to restart your source
to make it read out the EDID again.
Advanced EDID Management

support the EDID data structure. Source BIOS and operating systems
are likely to query the sink using DDC2B protocol to determine what
        


accepting the connected sink’s EDID information. In the case of EDID

signal.
Lightware devices provide the Advanced EDID Management function
that helps system integration. The built-in EDID Router can store and
emulate factory pre-programmed- and User programmable EDIDs. The
EDID of the attached monitors or projectors for each output are stored
in a non-volatile memory. This way the EDID of a monitor is available
when the monitor is unplugged or switched off.
Any EDID can be emulated on any input. An emulated EDID can be
copied from the EDID router’s memory (static EDID emulation), or
from the last attached monitor’s memory (dynamic EDID emulation).
For example, the Lightware device can be set up to emulate a sink
device, which is connected to one of the outputs. In this case, the EDID
automatically changes, if the monitor is replaced with another display
device (as long as it has a valid EDID).
EDID is independently programmable for all inputs without affecting
each other. All inputs have their own EDID circuit.
INFO: The user is not required to disconnect the video cable to
change an EDID as opposed to other manufacturer’s products.
EDID can be changed even if a source is connected to the input and
powered ON.
         
HOTPLUG signal for 2 seconds. Some sources do not sense this
signal. In such cases, the source device must be restarted or
powered OFF and ON again.

Table of Contents

Other manuals for Lightware HDMI-3D-OPT-RX150RA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware HDMI-3D-OPT-RX150RA and is the answer not in the manual?

Lightware HDMI-3D-OPT-RX150RA Specifications

General IconGeneral
BrandLightware
ModelHDMI-3D-OPT-RX150RA
CategoryReceiver
LanguageEnglish

Related product manuals