8-43
Chapter 8 FUEL SYSTEM
3.2 Fuel Control Link - Install
3.2.1 Control Link Lever - Install
(1) Install the link lever with ball bearing, snap ring and end plate to the bracket.
(2) Set the governor output shaft at "0" angle (fuel decreasing side) and the specified angle of governor lever, then engage the
serrated portion of the shaft.
3.2.2 Fuel Control Link - Install and Adjust
Fuel Control Link - Install and Adjust
5612
Distance from the end of fuel
injection pump to the rack end:
68 ± 0.5 mm [2.68 ± 0.02 in.]
Rack "0": 65 mm [2.60 in.]
Play: approx. 3 mm [0.12 in.]
65 ± 0.7 mm
[2.56 ± 0.028 in.]
Governor lever
Rack control lever
Stop lever
Fuel injection pump rack
Bracket
Ball bearing
End plate
Snap ring
Link lever
Control link
10°
Toho Seisakusho SG4017 actuator spec
Woodward DYNA 8000 Actuator spec
Woodward ProAct actuator spec
Woodward PSG governor spec
Woodward EG-3P governor spec
Woodward PSG governor spec
10°
35°
10°