12-12
Chapter 12 AIR START SYSTEM
2.7 Distributer Valve - Inspect
2.7.1 Distributer Valve Height - Measure
Measure the distributer valve height. If the value exceeds
the limit, replace the valve with a new one.
Distributer Valve Height - Measure
2.7.2 Clearance Between Distributer Shaft and
Bushing - Measure
Measure the clearance between the distributer shaft and
bushing. If the value exceeds the limit, replace the distrib-
uter shaft or bushing with a new one.
Clearance Between Distributer Shaft and Bushing
- Measure
Item Standard value Limit value
Distributer valve height
21.85 to 21.95 mm
[0.8602 to 0.8642 in.]
21.75 mm
[0.8563 in.]
Item Standard value Limit value
Clearance between shaft and
bushing
0.050 to 0.091 mm
[0.0020 to 0.0036 in.]
0.150 mm
[0.0059 in.]