4 Product description
Maschinenfabrik Reinhausen GmbH 202032 6385142/08 ENETOS
®
ED
4.5.1 Indication field
A clear indication field is fitted in the motor-drive unit. The pointer and opera-
tions counter are mechanically driven and indicate the tap-change operation
sequence and operating position of the motor-drive unit. The reset wheel on
the operations counter is sealed at the factory.
Figure8: Indication field
1 The two drag hands indicate the
regulating range currently used
2 Tap position indicator
3 Tap-change indicator: Shows the
current position of the control cam
(33 tap-change indicator sections
per operating position)
4 The mechanical operations
counter shows the overall number
of tap-change operations
4.5.2 Anti-condensation heater
The anti-condensation heater is designed as a panel heater which also acts
as the front cover of the swing frame.
The design of the motor-drive unit and panel heater ensures that air circu-
lates inside the motor-drive unit and therefore that there is a constant interior
temperature which is always higher than the outside temperature.
4.5.3 Swing frame/terminal rail
The swing frame protects all electrical and mechanical parts of the motor-
drive unit behind the swing frame against accidental contact.
The terminal rail behind the swing frame enables easy electrical connection
of the motor-drive unit. Vertically arranged cap rails with the correspondingly
mounted terminal bars ensure that the connection wiring is easy to install.