10 Fault elimination
Maschinenfabrik Reinhausen GmbH 2020 3616385142/08 EN ETOS
®
ED
Characteristics/details Cause Remedy
Plan OLTC maintenance
Event No. 1145
The limit value for planning mainte-
nance has been reached.
Plan maintenance and carry out maintenance
work soon, and then confirm this in the visual-
ization.
Maintenance work has been car-
ried out but not confirmed in the vi-
sualization.
Confirm maintenance work in the visualization.
Visualization operations counter
offset.
Compare visualization operations counter with
the motor-drive unit operations counter and
correct if necessary.
Maintenance data incorrect Call up the maintenance log and check the
date of the last maintenance work.
Oil change and cleaning required
Event No. 1171
The limit value for maintenance
has been reached.
Carry out maintenance work and then confirm
this in the visualization.
Maintenance work has been car-
ried out but not confirmed in the vi-
sualization.
Confirm maintenance work in the visualization.
Visualization operations counter
offset.
Compare visualization operations counter with
the motor-drive unit operations counter and
correct if necessary.
Maintenance data incorrect Call up the maintenance log and check the
date of the last maintenance work.
Plan oil change and cleaning
Event No. 1170
The limit value for planning mainte-
nance has been reached.
Plan maintenance and carry out maintenance
work soon, and then confirm this in the visual-
ization.
Maintenance work has been car-
ried out but not confirmed in the vi-
sualization.
Confirm maintenance work in the visualization.
Visualization operations counter
offset.
Compare visualization operations counter with
the motor-drive unit operations counter and
correct if necessary.
Maintenance data incorrect Call up the maintenance log and check the
date of the last maintenance work.
DSI must be replaced
Event No. 1150
The limit value for maintenance
has been reached.
Carry out maintenance work and then confirm
this in the visualization.
Maintenance work has been car-
ried out but not confirmed in the vi-
sualization.
Confirm maintenance work in the visualization.
Visualization operations counter
offset.
Compare visualization operations counter with
the motor-drive unit operations counter and
correct if necessary.
Maintenance data incorrect Call up the maintenance log and check the
date of the last maintenance work.