Section 4 HOW TO USE THE ADVANCED FUNCTIONS
4-32
HOW TO USE THE
ADVANCED FUNCTIONS
4.9 E24 Detection Enable/Disable (F10)
The H8PS Cam Positioner allows the output of an error display (E24) when the connector of the
connected Encoder is disconnected.
In normal operation the E24 detection function should be enabled to ensure safe operation.
If several H8PS Cam Positioner units are connected in parallel using a Y92C-30 Parallel Input Adapter, an
E24 error might be output even if the Encoder is connected correctly. To prevent this problem, the E24
error detection function must be disabled.
Whether the E24 error detection function is enabled or disabled is set using the F10 menu in the function
setting mode.
Parameter
* The default setting is "yes (enabled)".
8 output 16 output 32 output
Setting data Description
yes (enabled) In the RUN or TEST mode, the E24 error code is
displayed if the Encoder is not connected cor-
rectly.
no (disabled) E24 error is not detected.

Table of Contents