Section 3 HOW TO USE THE BASIC FUNCTIONS
3-6
HOW TO USE THE
BASIC FUNCTIONS
3.3.2 Setting the Rotation Direction
Set the rotation direction of the machine (Encoder).
■ Checking the Rotation Direction
Turn the machine (Encoder) in the direction of actual operation and
confirm that the rotation display monitor shows clockwise rotation.
(This can also be checked by observing the angle display values
increase as the Encoder turns).
Monitoring is possible in the following modes:
• Run mode (unconditionally)
• Test mode (only in the teaching mode)
■ Operation
Make sure that the power is off.
Open the front cover at the lower part of the H8PS and set pin 1 on the
DIP switch.
* Default setting.
*
OFF
ON
4321
DO NOT USECCW
OFF
OFF
ON
ON
OFF
ON
OFF
720 360
360360
360256
256256
ON
43
ANG
DSPL
PLS/R
CW
1888
1888888
8
8
55
r/ min
r/ min
/ 256
ADV
PV
SV
TST
RUN
PRG
1 2 3 4 5
6 7
8
ON OFF
5
CHECK
CAM
STEP
ON
OFF
ADV
ANGLE
SET
ORIGIN
CLEAR
PRGM
TEST
RUN
TCH
MAN
CAM
STEP
CW
ON
OFF
CCW DO NOT USE
1234
PLS/R
ANG
DSPL
ON
OFF
ON
ON
OFFOF F
OFF
ON
• When operating the DIP switch, use a tip of tweezers or a tool with a tip approximately
0.8 mm in width.
• The DIP switch settings are read to the H8PS Cam Positioner when the power is turned on.
• If the all protection function is active (Refer to "3.11 All Protection Function"), changing the
settings is not allowed and any attempt to do so is disregarded.
• Pin 2 on the DIP switch is not used and must remain in the factory setting.
Hint