1105
[Save Tone Control Value]
Stores the print gamma adjusted with the "Gamma Adj." menu item as the current setting.
Before the machine stores the new "current setting", it moves the data currently stored as
the "current setting" to the "previous setting" memory storage location.
1105 1 Save Tone Control Value
1106
[Toner Limit]
Adjusts the maximum toner amount for image development.
1106 1 Toner Limit Value *CTL [100 to 400 / 260 / 1 %/step ]
Engine SP
SP1-XXX (Feed)
1001
[Lead Edge Reg.] Leading Edge Registration
(Tray or By-pass, Paper Type, Process Speed)
Process Speed: LowSpd: Low Speed, HlfSpd: Half speed, NorSpd: Normal speed
• Adjusts the leading edge registration. This SP changes the registration clutch
operation timing for each mode.
•
A +ve value sets the registration start timing earlier.
• A –ve value sets the registration start timing later. The value of the normal paper in
RS is the standard value. The values of papers other than normal are added to the
value of the normal paper in RS.
002 T1:NorSpd 0.3mm *EGB [-9.0 to 9.0 / 0 / 0.3 mm/step]
003 T1:HlfSpd 0.3mm *EGB [-9.0 to 9.0 / 0 / 0.3 mm/step]
006 T2:NorSpd 0.3mm *EGB [-9.0 to 9.0 / 0 / 0.3 mm/step]
007 T2:HlfSpd 0.3mm *EGB [-9.0 to 9.0 / 0 / 0.3 mm/step]
014 ByPas:NorSpd 0.3mm *EGB [-9.0 to 9.0 / 0 / 0.3 mm/step]
015 ByPas:HlfSpd 0.3mm *EGB [-9.0 to 9.0 / 0 / 0.3 mm/step]
Main SP Tables: 1
101