RIGOL 2 Command System
2-148 DS2000E Programming Guide
:MEASure:FDELay
Syntax 1
:MEASure:FDELay <chanA>,<chanB>
Description 1
Enable the delay (falling edge-falling edge) measurement function between the two specified channels.
Syntax 2
:MEASure:FDELay? <chanA>,<chanB>
Description 2
Enable the delay (falling edge-falling edge) measurement function between the two specified channels
and return the measurement result (the unit is s).
Parameter
Name Type Range Default
<chanA> Discrete {CHANnel1|CHANnel2} --
<chanB> Discrete {CHANnel1|CHANnel2} --
Return Format
The query returns the delay (falling edge-falling edge) measurement result in scientific notation. When
the measurement result is invalid, the query returns 9.9e37.
Example
:MEASure:FDELay CHANnel1,CHANnel2
:MEASure:FDELay? CHANnel1,CHANnel2
You can use the following commands to enable the delay (falling edge-falling edge) measurement
function between the two specified channels and the statistic function of the measurement results as well
as query the statistic maximum value, minimum value, current value, average value, and standard
deviation of the delay (falling edge-falling edge) measurement results.
:MEASure:FDELay:SMAXimum
:MEASure:FDELay:SMINimum
:MEASure:FDELay:SCURrent
:MEASure:FDELay:SAVerage
:MEASure:FDELay:SDEViation

Table of Contents

Other manuals for Rigol DS2000E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS2000E Series and is the answer not in the manual?

Rigol DS2000E Series Specifications

General IconGeneral
BrandRigol
ModelDS2000E Series
CategoryTest Equipment
LanguageEnglish

Related product manuals