RIGOL 2 Command System
2-316 DS2000E Programming Guide
:WAVeform Commands
The :WAVeform commands are used to read the waveform data and its related settings.
The
:WAVeform:MODE command is used to set the reading mode of the waveform data. In different
mode, the definition of each parameter is different, as shown in Figure 2-1 and Figure 2-2.
Figure 2-1 Parameter Definitions in NORMAL Mode
Figure 2-2 Paramter Definitions in RAW Mode
XORigion
YORigion
YREFerence
YINCrement=Vscale/25
XINCrement=1/SampleRate
XORigion
YORigion
YREFerence
YINCrement=Verticalscale/25
XINCrement=TimeScale/100
XREFerence
XREFerence