EasyManuals Logo
Home>Rigol>Test Equipment>DS2000E Series

Rigol DS2000E Series Programming Guide

Rigol DS2000E Series
365 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #277 background imageLoading...
Page #277 background image
2 Command System RIGOL
DS2000E Programming Guide
2-261
:TRIGger:EDGe
:TRIGger:EDGe:LEVel
:TRIGger:EDGe:SLOPe
:TRIGger:EDGe:SOURce
:TRIGger:EDGe:LEVel
Syntax
:TRIGger:EDGe:LEVel <level>
:TRIGger:EDGe:LEVel?
Description
Set or query the trigger level of edge trigger when the trigger source is CHANnel1, CHANnel2, or EXT. The
unit is the same with the current amplitude unit.
Parameter
Name Type Range Default
<level> Real
When the trigger source is CHANnel1 or CHANnel2:
(-5 x VerticalScale - OFFSet) to (+5 x VerticalScale - OFFSet)
When the trigger source is EXT: -4V to 4V
0
Note: For the VerticalScale, refer to the :CHANnel<n>:SCALe command. For the OFFSet, refer to
the
:CHANnel<n>:OFFSet command.
Explanation
To set the trigger source of edge trigger, please refer to the
:TRIGger:EDGe:SOURce command.
When the trigger source of edge trigger is ACLine, you do not need to set this parameter.
Return Format
The query returns the trigger level of edge trigger when the trigger source is CHANnel1, CHANnel2, or
EXT in scientific notation.

Table of Contents

Other manuals for Rigol DS2000E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS2000E Series and is the answer not in the manual?

Rigol DS2000E Series Specifications

General IconGeneral
BrandRigol
ModelDS2000E Series
CategoryTest Equipment
LanguageEnglish

Related product manuals