Page #343 background imageLoading...
Page #343 background image
2 Command System RIGOL
DS2000E Programming Guide
2-327
:WAVeform:STARt
Syntax
:WAVeform:STARt <sta>
:WAVeform:STARt?
Description
Set or query the start point of waveform data reading.
Parameter
Name Type Range Default
<sta> Integer
NORMal: 1 to 1400
MAXimum: 1 to the number of effective point currently on the
screen
RAW: 11 to the current maximum memory depth
1
Explanation
For the memory depth, refer to the
:ACQuire:MDEPth command.
The range of the start point is limited by the current mode of waveform data reading (refer to
the
:WAVeform:MODE command).
When the waveform data in the internal memory are read, the range of start point and stop point
(refer to the
:WAVeform:STOP command) is related to the current maximum number of the
waveform points that can be read for a single time. For details, refer to descriptions in
the
:WAVeform:DATA? command.
Return Format
The query returns the start point of waveform data reading in integer.

Table of Contents

Other manuals for Rigol DS2000E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS2000E Series and is the answer not in the manual?

Rigol DS2000E Series Specifications

General IconGeneral
BrandRigol
ModelDS2000E Series
CategoryTest Equipment
LanguageEnglish

Related product manuals