2 Command System RIGOL
DS2000E Programming Guide
:MEASure:PVRMs:SMAXimum
:MEASure:PVRMs:SMINimum
:MEASure:PVRMs:SCURrent
:MEASure:PVRMs:SAVerage
:MEASure:PVRMs:SDEViation
Syntax 1
:MEASure:PVRMs:SMAXimum <chan>
:MEASure:PVRMs:SMINimum <chan>
:MEASure:PVRMs:SCURrent <chan>
:MEASure:PVRMs:SAVerage <chan>
:MEASure:PVRMs:SDEViation <chan>
Description 1
Enable the RMS value measurement function within a single period of the specified channel and the
statistic function of the measurement results.
Syntax 2
:MEASure:PVRMs:SMAXimum? <chan>
:MEASure:PVRMs:SMINimum? <chan>
:MEASure:PVRMs:SCURrent? <chan>
:MEASure:PVRMs:SAVerage? <chan>
:MEASure:PVRMs:SDEViation? <chan>
Description 2
Query the statistic maximum value (SMAXimum), minimum value (SMINimum), current value (SCURrent),
average value (SAVerage), or standard deviation (SDEViation) of the RMS value measurement results
within a single period when the RMS value measurement function within a single period of the specified
channel and the statistic function of the measurement results are enabled.
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Explanation
The unit is determined by the unit selected for the signal source channel (refer to
the
:CHANnel<n>:UNITs command).
Return Format
The query returns the statistic maximum value, minimum value, current value, average value, or standard
deviation of the RMS value measurement results within a single period in scientific notation. When the
measurement results are invalid, the query returns 9.9e37.