EasyManuals Logo
Home>SEW-Eurodrive>DC Drives>MOVIMOT flexible MMF1 C/DBC Series

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series User Manual

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
6
Startup
Configuring the digital inputs/outputs
Operating Instructions – MOVIMOT
®
flexible
162
6.10 Configuring the digital inputs/outputs
Easy mode (deliv-
ery state)
In Easy mode, the following configuration of the digital inputs is active:
Digital inputs
Function
(Configuration of the digital inputs)
Setting
(CW/CCW/setpoint changeover)
DI01
Fixed setpoints, positive rotation direc-
tion
DI02
Fixed setpoints, negative rotation direc-
tion
DI03
Potentiometer f2
DI04
Fault reset
Digital outputs
Function Setting
DOR (relay output) Ready for operation
Expert mode In Expert mode, you can assign other functions to the digital inputs and to the relay
output, either individually or using predefined configurations of the digital inputs.
29129451/EN – 12/2019

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series and is the answer not in the manual?

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series Specifications

General IconGeneral
BrandSEW-Eurodrive
ModelMOVIMOT flexible MMF1 C/DBC Series
CategoryDC Drives
LanguageEnglish

Related product manuals