TB9100/P25 CG/P25 TAG Installation and Operation Manual Installation 49
© Tait Limited March 2014
5. Read the base station’s configuration.
6. Select Configure > Channel Group > Network.
7. Enter the subnet and the IP address specified for this base station by
the IP addressing plan for the network. Also enter a suitable name for
the base station.
Notice Be careful to enter the correct address and subnet, and to keep
a written record of them. If you give the base station an unknown IP
address or subnet, the CSS will be unable to connect to it.
8. Click OK to confirm your entry and exit the configuration form.
9. Click “Tools > Connections” and add an entry to the connections
list, consisting of the name and IP address you have entered.
10. Make any other configuration changes that are required (see
“Customizing the Configuration” below, and click Save to save them
to file.
11. On the toolbar, click Program to program the information into the
base station.
12. Click Overwrite to confirm that you really do want to change the
IP address.
13. Reset the base station so that the new IP address and name take effect.
This disconnects the CSS.
14. Make sure that the CSS PC’s IP address and subnet allow it to connect
to the base station’s new IP address.
15. If necessary, wait for the base station to power up, then on the toolbar,
click the Connect icon.
16. Select the entry you added to the connection list and click Connect.
17. In the status bar, verify that you are actually connected to the base
station.
Finding a Lost or Forgotten IP Address
Use the following procedure if an IP address has been lost or forgotten.
1. Connect your PC to the 9-pin serial connector on the back of the
reciter.
2. Run a program such as HyperTerminal, Teraterm or minicom.
3. Select the following port settings: 57600 baud, 8 bits, no parity, 1 stop
bit, no flow control.

Table of Contents

Other manuals for Tait TB9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tait TB9100 and is the answer not in the manual?

Tait TB9100 Specifications

General IconGeneral
BrandTait
ModelTB9100
CategoryAccessories
LanguageEnglish

Related product manuals