Using offset to avoid clipping signals
Using Offset to Avoid Clipping Signals
Clipping
The circled portion of the incoming waveform is clipped, and
therefore, is not acquired.
The clipped portion cannot be processed or displayed.
Offset can move the acquisition window vertically relative to the
incoming waveform.
Offset removes clipping
By setting an offset to vertically shift the acquisition positive relative
to the waveform, the clipped portion can be acquired.
Termination controls
From the Vertical menu, select Termination.
Overview
Use the Termination control window to select the channel input resistance.
For MSO/DPO70000C/DX model oscilloscopes, Termination is fixed at 50 Ω.