To use. Setups are recalled from an internal file on your hard drive or from a setup file that you have named.
â– 
Under Recall What, click Setup.
â– 
Click one of the icons under Look in: Oscilloscope Memory, and then click the Recall button to restore the setup.
â– 
Click the Factory Defaults icon to recall the default factory setup for the instrument.
TIP. Select the File menu Recall Default Setup command to instantly restore the default setup.
To recall an instrument setup from a file, select the location of the setup from the Look in list. Select the setup you want to recall,
and then click Recall.
Behavior. The setups are restored from an internal file on your hard drive as soon as you click the Recall button. The labels
adjacent to the icons were created when the setups were first saved. Any of the setups with the label "Factory" will restore the
default factory setups.
The data in reference waveforms is not saved with the instrument setup. However, the setup information does include which
reference waveforms are turned on and which reference waveforms are used with math waveforms and automatic
measurements. If you want to save the reference waveform data, save the reference waveform separate from the instrument
setup. You can then recall the saved waveform to the setup from the Reference Waveform Controls.
NOTE. If a restored setup attempts to use an undefined reference waveform (or to use it in a math waveform or with an
automatic measurement), then an undefined reference waveform is created. This reference waveform becomes a 500-point
waveform filled with null data. Any math waveforms or any measurements done on this waveform will contain invalid or unusable
data. However, you can recall a valid saved waveform to the new reference waveform so that the math waveforms and the
automatic measurements will become valid.
What do you want to do next?
Learn about saving instrument setups.
Learn about deleting instrument setups.
Delete setups and reference waveforms
From the File menu highlight Delete; then select an entry in the submenu.
Overview. Use this dialog box to delete a saved reference waveform or setup file.
To use.
â– 
Select the setup or reference waveform you want to delete.
â– 
To delete all Setups at the same time, select All Setups
â– 
To delete All Reference Waveforms at one time, select All Refs.
File menu
DPO70000SX, MSO/DPO70000DX, MSO/DPO70000C, DPO7000C, and MSO/DPO5000B Series 533

Table of Contents

Other manuals for Tektronix DPO5034B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO5034B and is the answer not in the manual?

Tektronix DPO5034B Specifications

General IconGeneral
BrandTektronix
ModelDPO5034B
CategoryTest Equipment
LanguageEnglish

Related product manuals