3-92 BA 50Z3/6003 en – Edition 4.3 * * 5003b340.fm
Operation
Adjusting control response
Characteristic curve 1 (slow movements)
☞ Switch off ignition.
☞ Press and hold slide switch B toward D.
☞ Switch on ignition at the same time.
☞ Wait 2 seconds and then release slide switch B.
➥ Status indicator 52 acknowledges by flashing once.
Characteristic curve 2 (fast movements – maximum throughput)
☞ Switch off ignition.
☞ Press and hold slide switch B toward C.
☞ Switch on ignition at the same time.
☞ Wait 2 seconds and then release slide switch B.
➥ Status indicator 52 acknowledges by flashing twice.
Characteristic curve status indicator
Displays the characteristic curve that has been selected for the control valve.
Characteristic curve 1 (slow movements)
➥ Indicator light 1 in status indicator 52 flashes once after switching on ignition.
Characteristic curve 2 (fast movements – maximum throughput)
➥ Indicator light 1 in status indicator 52 flashes twice after switching on ignition.
The characteristic curve that has been set last is active after the machine is started
again.
Fig. 186: Adjusting control response
B
D
C
Fig. 187: Characteristic curves – status indicator (up to
serial no. AH02781)
1
52
Fig. 187: Characteristic curves – status indicator (from
serial no. AJ02777)
1
52