BA 50Z3/6003 en – Edition 4.3 * 5003b530.fm 5-55
Maintenance
Oil grades for the diesel engine, depending on temperature
Additional oil change and filter replacement (hydraulic system)
Caution!
An additional oil change and filter replacement can be required depending on
how the machine is used. Failure to observe these replacement intervals can
cause damage to hydraulic components.
☞ Observe the following intervals
Notice!
Please refer to the maintenance plan on page 5-57 for additional maintenance
work.
Engine oil grade Ambient temperature (°C)
API CF, CF-4, CI-4;
ACEA E3, E4, E5;
JASO DH-1
°C
-20-15-10-5 0 5 10152025303540
SAE 10W
SAE 20W
SAE 10W-40
SAE 15W-40
SAE 20
SAE 30
SAE 40
°F
-4 5 14233241505968778695104
Application Hydraulic oil Hydraulic oil filter insert
Normal work (excavation work)
Every 1000 s/h
Replace the first time after 50 s/h, then every 500 s/h
Percentage of hammer work
20 % Every 800 s/h
300 s/h
40 % Every 400 s/h
60 % Every 300 s/h
100 s/h
Over 80 % Every 200 s/h