Marine Installation Manual 2022-03 3-7
3 Engine Installation
3.2 Conditions and requirements
X62DF-S2.0
3.2.4 Electrical power requirement
Table 3-2 Electrical power requirement
No.
cyl.
Power requirement [kW] Power supply
Auxiliary blowers
a)
a) Minimal electric motor power (shaft) is indicated. Actual electric power requirement de-
pends on size, type and voltage / frequency of installed electric motor. Direct starting or
Star-Delta starting to be specified when ordering.
5 2 x 43
440V / 60Hz
6 2 x 50
7 2 x 60
8 2 x 67
Turning gear
5 5.5
440V / 60Hz
6 5.5
7 5.5
8 5.5
Engine control system
5 0.7
220V / 60Hz
6 0.7
7 0.8
8 1.0
Pilot fuel pump
All 12.8 440V / 60Hz
Propulsion control system
All Acc. to maker’s specifications 24 VDC (UPS)
Additional monitoring devices (e.g. oil mist detector, etc.)
All Acc. to maker’s specifications