ACSM1 More parameters read from drive to PLC (optional)
Parameter
Description
Setting
Comment
52.03
52.12
Actual value or
parameter of drive
GGii
GG = parameter group, ii = parameter index
Example, 0104 = actual current; 0117 = motor temp
51.27
FBA PAR
REFRESH
REFRESH
Updates fieldbus settings (groups 50 to 53)
ACSM1 More parameters written from PLC to drive (optional)
Parameter
Description
Setting
Comment
53.03
53.12
Parameter of
drive
GGii
GG = parameter group, ii = parameter index
Example, 2503 = acceleration time
51.27
FBA PAR
REFRESH
REFRESH
Updates fieldbus settings (groups 50 to 53)

Table of Contents