26-9
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Software Configuration Guide
OL-14127-08
Chapter 26 Upgrading Field-Programmable Devices
Troubleshooting Problems with FPD Image Upgrades
% NOTES:
- Use 'show upgrade fpd progress' command to view the progress of the FPD
upgrade.
- The target card will be automatically reloaded after the upgrade
operation. This reload will interrupt normal operation of the card. If
necessary, ensure that appropriate actions have been taken to redirect
card traffic before starting the FPD upgrade.
% Are you sure that you want to perform this operation? [no]: yes
% Initiating the upgrade operation on the target card ...
(Use "show upgrade fpd progress" command to see upgrade progress)
Router#
*Mar 4 16:15:22.862: %FPD_MGMT-6-UPGRADE_TIME: Estimated total FPD image upgrade time for
SPA-2XT3/E3 card in subslot 0/3 = 00:01:00.
*Mar 4 16:15:22.864: %FPD_MGMT-6-UPGRADE_START: I/O FPGA (FPD ID=2) image upgrade in
progress for SPA-2XT3/E3 card in subslot 0/3. Updating to version 1.1. PLEASE DO NOT
INTERRUPT DURING THE UPGRADE PROCESS (estimated upgrade completion time = 00:01:00) ...
*Mar 4 16:15:47.795: %FPD_MGMT-6-UPGRADE_PASSED: I/O FPGA (FPD ID=2) image in the
SPA-2XT3/E3 card in subslot 0/3 has been successfully updated from version 1.0 to version
1.1. Upgrading time = 00:00:24.931
*Mar 4 16:15:47.795: %FPD_MGMT-6-OVERALL_UPGRADE: All the attempts to upgrade the
required FPD images have been completed for SPA-2XT3/E3 card in subslot 0/3. Number of
successful/failure upgrade(s): 1/0.
*Mar 4 16:15:47.796: %FPD_MGMT-5-CARD_POWER_CYCLE: SPA-2XT3/E3 card in subslot 0/3 is
being power cycled for the FPD image upgrade to take effect.
Troubleshooting Problems with FPD Image Upgrades
This section contains information to help troubleshoot problems that can occur during the upgrade
process.
It contains the following topics:
• Power Failure or Removal of a SPA During an FPD Image Upgrade, page 26-9
• Performing an FPD Recovery Upgrade, page 26-10
• Verifying a Successful Upgrade, page 26-12
Power Failure or Removal of a SPA During an FPD Image Upgrade
These instructions should only be used if a previous upgrade attempt has failed due to an external factor
such as a power failure or a SPA removal.
If the FPD upgrade operation is interrupted by a power failure or the removal of the SPA, it could corrupt
the FPD image. This corruption of the FPD image file makes the SPA unusable by the router and the
system will display the following messages when it tries to power up the SPA:
Note To find more information about FPD-related messages, check the system error messages guide for your
Cisco IOS XE software release.
Nov.28 11:30:36:%SPA_OIR-3-RECOVERY_RELOAD:subslot 0/1:Attempting
recovery by reloading SPA
Nov.28 11:30:51:%SPA_OIR-3-HW_INIT_TIMEOUT:subslot 0/1
Nov.28 11:30:56:%SPA_OIR-3-RECOVERY_RELOAD:subslot 0/1:Attempting
recovery by reloading SPA