6 Command Line Interface D-Link Smart Managed Switch User Manual
1
1
3
3
9
9
DGS-1210-52MP> download firmware_fromTFTP 1.1.1.23 1\dgs_1210-10032.ros image_id 1
01Jan2000 01:19:48 %COPY–I–FILECPY: Files Copy source URL tftp://1.1.1.23 /1\
dgs_121010032.ros destination URL Unit all flash://image
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!01Jan2000 01:22:49 %COPY–W–TRAP:
The copy operation was completed successfully
!
3920460 bytes copied in 00:03:01 [hh:mm:ss]
DGS-1210-52MP>
Note: Switch will reboot after restore and
all current configurations will be lost.
upload
Purpose To upload the firmware file or a Switch configuration file to a
TFTP server.
Syntax
upload {firmware_toTFTP {<ipaddr>| <ipv6addr>}
<path_filename (64)> image_id <integer 1-2> | cfg_toTFTP
{<ipaddr>| <ipv6addr>} <path_filename (64)>}
Description
The upload command uploads the Switch’s current settings to a
TFTP server.
Parameters
firmware_toTFTP
Upload the firmware on the Switch from a
TFTP server.
cfg_toTFTP Specifies that the Switch’s current settings will be
uploaded to the TFTP server.
<ipaddr> The IPv4 address of the TFTP server.
<ipv6addr> The IPv6 address of the TFTP server.
<path_filename 64>
The filename of the firmware or switch
configuration file on the TFTP server. You need to specify the
DOS path if the file is not at the root directory of the TFTP server.
image_id <integer 1-2> - Specifies the image id to be configured.
Restrictions None.

Table of Contents

Other manuals for D-Link DGS-1210-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DGS-1210-10 and is the answer not in the manual?

D-Link DGS-1210-10 Specifications

General IconGeneral
Switching Capacity20 Gbps
Forwarding Rate14.88 Mpps
MAC Address Table Size8K
VLANs256
Jumbo Frame9, 216 bytes
Fanless DesignYes
Humidity5% to 95% non-condensing
Ports8 x 10/100/1000Base-T, 2 x SFP
Dimensions280 x 180 x 44 mm
Operating Temperature0 to 40 °C
Storage Temperature-40 to 70 °C