OPERATION
3-34 L025317 Issue 1 March 2011
Mode Type
Allows selection of the following:
Disabled - Disables "Insert" functions.
OEM Select - Causes the marking of a text insert based on a binary
representation placed on the OEM Select port.
Timer - Causes the change of marking a text insert after a fixed elapsed time
in seconds.
Tr igger - Causes the increment of a text insert using either a printstart
trigger or user input as chosen in the "trigger" option.
Level - Causes the marking of a text insert based on the state of the selected
input. If the selected user input state is active, the insert will be marked.
Otherwise, it’s place will be filled with space characters.
Depending on the Mode selection chosen, the following parameters will need
setting:
Text Length - Sets the maximum number of combined letters and numbers
for each of the inserts.
Increment Interval - Time interval between each insert line.
Tr igger Timer - Triggers the insert line by using either a printstart signal or
user input (rising and falling edge signals).
Input - Selects which user input signal is used (not for printstart).
Initial Text Index - Index of the initial text.
Auto Repeat - Number of insert repeats before the insert will increment.
Insert - Allows you to place an insert.
Insert before - Allows you to place an insert line before the selected line.
Insert after - Allows you to place an insert line after the selected line.