EasyManuals Logo
Home>Domino>Label Maker>D Series

Domino D Series User Manual

Default Icon
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
INSTALLATION
2-36 L025317 Issue 1 March 2011
Connection of Compressed Air to the Laser
WARNING: Maximum operating air pressure is 3.5 bar!
Connect the hose from the air installation kit to the laser compressed air inlet.
A pressure control valve is at the air inlet. It limits the air flow into the laser
cabinet to 450 liters per minute and opens at a supply pressure above 3 bar.
For safety reasons there are two seperate outlets for compressed air. To one of
them a non return valve and a silencer are connected (Air Outlet 2). A hose is
connected to the other one (Air Outlet 1). The end of the hose must be
installed so that the hose neither gets blocked nor is infiltrated by water. Please
check the outlets for blocking and dirt on a regular monthly basis. Blocked
outlets may damage the laser!
The throttle valve for lens air flow is optional. This connection is normally
sealed with a blank plug. The outlet of the pressure control valve must not be
directed to any person.
Air Outlet 1
with connected hose
Air Outlet 2
with silencer and non
return valve
Air Inlet
Air Outlet 2
with silencer and non
return valve
Compressed air to lens
(Sealed with blank plug)
Pressure control valve
Do not change the setup.
Air Outlet 1
with connected hose

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Domino D Series and is the answer not in the manual?

Domino D Series Specifications

General IconGeneral
BrandDomino
ModelD Series
CategoryLabel Maker
LanguageEnglish