EasyManuals Logo
Home>Domino>Label Maker>D Series

Domino D Series User Manual

Default Icon
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
INSTALLATION
L025317 Issue 1 March 2011 2-37
Note: Contact Domino. before disconnecting the silencer or connecting a hose to
the air outlet 2 at the laser.
If two hoses are used for the compressed air outlets these have always to be
seperated from each other and to be placed in differnt ways for safety
reasons.
Both air outlets must be kept clear. Only one silencer has to be installed to the
air outlets. Do not use silencers on both air outlets. Do not swap compressed
air inlets and outlets.
Minimum diameter of the outlet hose must be 12 mm. The length of the
outlet hose must not exceed 4 m.
AIR FLOW SETTINGS
To adjust the air flow increase the pressure until the pressure control valve
opens. This pressure is the maximum pressure and is equivalent to 450 liters
per minute (lpm) air flow. Set the air flow rate according to the following
table:
All curves are recorded with the original D-Series air kit. The maximum hose
length when an air chiller is used is 4 meters from the chiller to the laser head.
In this case the air kit is installed between air chiller and laser head. An air
chiller type SMC (Modell: IDFA8E) has been used as reference.
The actual pressure depends on the installed length of the installed hose.
Flow rate (lpm) Pressure Percentage of P
max
450 P
max
100
400 0.9 x P
max
90
300 0.65 x P
max
65
200 0.4 x P
max
40
150 0.3 x P
max
30

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Domino D Series and is the answer not in the manual?

Domino D Series Specifications

General IconGeneral
BrandDomino
ModelD Series
CategoryLabel Maker
LanguageEnglish