OPERATION
L025317 Issue 1 March 2011 3-37
(8) Click on the Back button, select Next and OK to complete this
example as shown below.
OEM Message Select
Messages may be activated for printing by a combination of input signals and a
strobe signal via the user port. The input signals have to be set before sending
the strobe signal (user input H) to the controller.
To activate a message the sum of the binary representation value of the inputs
is used:
• User Input A - 1
• User Input B - 2
• User Input C - 4
• User Input D - 8
• User Input E - 16
• User Input F - 32
• User Input G - 64
Examples
If message 0 shall be printed set all user inputs low. HELP_
If message 1 shall be printed set user input A high and all other low. HELP_
If message 3 shall be printed set user input A and B high and all other low.
If message 13 shall be printed set user input A, C and D high and all other
low. For a description of the user port see the "Options Guide".