INSTALLATION
L025317 Issue 1 March 2011 2-21
The drawing shows two different ways how to connect a fume extraction
system:
•with relay or
logic input.
Connector Type: IEC 60130-9 Type 6 way male
Mating Cable Connector (IP67 Types) :
Lumberg: 032206
Pin description
Pin 1 VAC_OK - Extraction system running input
A correctly running extraction system delivers a high level signal at this pin.
Input Impedance: 1kOhm, Input range 10-30V
Pin 2 GNDF - Floating Ground
Pin 3 FILTER_OK - IN Filter clean input
A clean filter delivers high level at this pin.
Input Impedance: 1KOhm , Input range 10-30V
Pin 4 VAC_ON_+COM - Solid State Relay – Vacuum ON – Relay
positive Common
Pin 5 VAC_ON_NO - Solid State Relay- Vacuum ON - DC
This output is used to switch on the Vacuum system by a solid state relay
(max. Voltage: 50V, maximum current for X3/X6 and X7 is 0.5A. In case of
an overcurrent an autmatic resetable fuse protects the system)
Pin 6 +24VF- 24V floating
This pin can be used to drive the chiller control relay (pin 4) or to supply the
feedback signals (maximum current for X3 and X6 and X7 and X21
(optional user port) is 0.5A. In case of an overcurrent an automatic resetable
fuse protects the system)