set spantree hello
9-18 Spanning Tree Configuration
Defaults
Ifsidisnotspecified,prioritywillberesetonSpanningTree0.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresetthebridgepriorityonSID1:
C2(su)->clear spantree priority 1
set spantree hello
Usethiscommandtosetthedevice’sSpanningTreehellotime,Thisisthetimeinterval(in
seconds)thedevicewilltransmitBPDUsindicatingitisactive.
Syntax
set spantree hello interval
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtogloballysettheSpanningTreehellotimeto10seconds:
C2(su)->set spantree hello 10
clear spantree hello
UsethiscommandtoresettheSpanningTreehellotimetothedefaultvalueof2seconds.
Syntax
clear spantree hello
Parameters
None.
Defaults
None.
interval Specifiesthenumberofsecondsthesystemwaitsbeforebroadcastinga
bridgehellomessage(amu lticastmessageindicatingthatthe systemis
active).Validvaluesare1‐10.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals