set dhcp pool netbios-node-type
SecureStack C2 Configuration Guide 16-27
Mode
Switchcommand,readwrite.
Example
ThisexampleremovestheNetBIOSnameserverlistfromtheaddresspoolauto1.
C2(rw)->clear dhcp pool auto1 netbios-name-server
set dhcp pool netbios-node-type
UsethiscommandtospecifyaNetBIOSnode(server)typefortheDHCPclientsservedbythe
addresspoolbeingconfigured.
Syntax
set dhcp pool poolname netbios-node-type {b-node | h-node | p-node | m-node}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexamplespecifieshybridastheNetBIOSnodetypefortheaddresspool“auto1.”
C2(rw)->set dhcp pool auto1 netbios-node-type h-node
clear dhcp pool netbios-node-type
UsethiscommandtoremovetheNetBIOSnodetypefromtheaddresspoolbeingconfigured.
Syntax
clear dhcp pool poolname netbios-node-type
Parameters
poolname Specifiesthenameoftheaddresspool.Poolnamesmaybeupto31
charactersinlength.
bnode SpecifiestheNetBIOsnodetypetobebroadcast(noWINS).
hnode SpecifiestheNetBIOsnodetypetobehybrid(WINS,thenbroadcast).
pnode SpecifiestheNetBIOsnodetypetobepeer(WINS
only).
mnode SpecifiestheNetBIOsnodetypetobemixed(broadcast,thenWINS).
poolname Specifiesthenameoftheaddresspool.Poolnamesmaybeupto31
charactersinlength.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals