EasyManuals Logo

Enterasys SecureStack C2 C2G170-24 User Manual

Enterasys SecureStack C2 C2G170-24
698 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #685 background image
show pwa session
SecureStack C2 Configuration Guide 23-71
Parameters
Defaults
Ifportstringisnotspecified,PWAwillenabledonallports.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoenablePWAonports122:
C2(su)->set pwa portcontrol enable ge.1.1-22
show pwa session
UsethiscommandtodisplayinformationaboutcurrentPWAsessions.
Syntax
show pwa session [port-string]
Parameters
Defaults
Ifportstringisnotspecified,sessioninformationforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayPWAsessioninformation:
C2(su)->show pwa session
Port MAC IP User Duration Status
-------- ----------------- --------------- ------------- ------------ ---------
ge.2.19 00-c0-4f-20-05-4b 172.50.15.121 pwachap10 0,14:46:55 active
ge.2.19 00-c0-4f-24-51-70 172.50.15.120 pwachap1 0,15:43:30 active
ge.2.19 00-00-f8-78-9c-a7 172.50.15.61 pwachap11 0,14:47:58 active
enable|disable EnablesordisablesPWAonspecifiedports.
portstring (Optional)Setsthecontrolmodeonspecificport(s).Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 72.
portstring (Optional)DisplaysPWAsessioninformationforspecificport(s).Fora
detaileddescriptionofpossibleportstringvalues,referto PortString
SyntaxUsedintheCLIonpage 72.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals